PHARMACEUTICAL IMPURITY STANDARD
NO.1 SUPPLIER & MANUFACTURER
Run for science and technology, promote human health
PHARMACEUTICAL IMPURITY STANDARD NO.1 SUPPLIER & MANUFACTURER
Run for science and technology, promote human health
Location: Home > NEWS & INSIGHTS

2024V19 | Sharing research on the stability of brain metabolic activator Citicoline specific impurities

Time:2024-08-23


Introduction

Today, we will share the research on the stability of brain metabolic activator Citicoline specific impurities. Citicoline is a brain metabolic activator that can promote respiration of brain cells, improve brain function, enhance the function of the ascending reticular formation activation system, promote awakening, and reduce cerebral vascular resistance.



Experimental scheme

In this experiment, our center conducted a solution stability study on two specific impurities of Citicoline using the chromatographic conditions used under the "RELATED COMPOUNDS" item of the "Citicoline" variety in the USP-NF2024 edition of the United States Pharmacopeia. The sample item number and structural formula used are shown in Figure 1 and Figure 2:


1.png 

Figure 1: The impurity item number and structural formula used in this study

 

Research on Specific Impurities

2.png 

Figure 2: Corresponding relationship diagram between impurity codes included in the standard and impurity item numbers used in this study


In this experiment, the experimenter placed appropriate amounts of RM-C252001 ([5 '] Cytidylic Acid Monomethyl Ester; CAS: 52448-10-9) and RM-U090901 (Uridine Diphosphate Choline [UDPC]; CAS: 99492-83-8) in acidic, neutral, and alkaline solutions, respectively, at room temperature and pressure for 0, 3, 6, 12, and 24 hours, and then injected the samples for detection according to the chromatographic conditions used under the "RELATED COMPOUNDS" item of the "Citicoline" variety in the USP-NF2024 edition of the United States Pharmacopeia. The chromatograms were observed as the sample solution was left for an extended period of time. The change in peak area of the main peak is used as a basis to determine the solution stability of the sample.


                            

Empirical conclusion


After testing, it was found that the main peak area of samples RM-C252001 and RM-U090901 (UDPC) did not change significantly during 24 hours of storage in acidic, neutral, and alkaline solutions, and the relative standard deviation was less than 2.0%. So it can be considered that the two samples are relatively stable when placed in acidic, neutral, and alkaline solutions for 24 hours. The main peak area data of each detection point under various pH conditions of the sample are as follows:


3.png 

Figure 3: Summary line chart of solution stability data for sample RM-C252001

 

4.png 

Figure 4: Summary line chart of solution stability data for sample RM-U090901 (UDPC)


In summary, through this stability experiment, we found that samples RM-C252001 and RM-U090901 (UDPC) have good stability under acid-base neutral conditions. The only thing to note is that RM-U090901 (UDPC) has strong hygroscopicity, so more attention should be paid during weighing and transfer. Firstly, if possible, try to weigh in a glove box; The second is that the weighing process should be as fast as possible; Thirdly, this product is not suitable for repeated weighing, and it is recommended to purchase small packaging as much as possible. If customers have a need for the stability of these two samples, welcome to consult our company.


屏幕截图 2024-04-15 092448.jpg



Back

CONTACT US

Service hotline: +86 0755-66853366
Marketing Department: +86 136 7004 6396 (WeChat)
Email: sales@chem-strong.com
Office address: Room 1201, Jiaye Plaza, No. 2055, Bixin Road, Longgang District, Shenzhen

*All of our products are for R&D use only, and cannot be used in human or animal clinical use

FOLLOW US

ChemStrong

QCS R&D Center

Copyright 2006-2024 © ShenZhen ChemStrong Scientific Co., Ltd. 备案号:粤ICP备19155981号 Shenzhen Municipal Administration for Market Regulation Enterprise Identity Disclosure

CONTACT US

Service hotline: +86 0755-66853366
Marketing Department: +86 136 7004 6396 (WeChat)
Email: sales@chem-strong.com
Office address: Room 1201, Jiaye Plaza, No. 2055, Bixin Road, Longgang District, Shenzhen
*All of our products are for R&D use only, and cannot be used in human or animal clinical use

FOLLOW US

ChemStrong

QCS R&D Center

Copyright 2006-2024 © ShenZhen ChemStrong Scientific Co., Ltd. 备案号:粤ICP备19155981号 Shenzhen Municipal Administration for Market Regulation Enterprise Identity Disclosure