PHARMACEUTICAL IMPURITY STANDARD
NO.1 SUPPLIER & MANUFACTURER
Run for science and technology, promote human health
PHARMACEUTICAL IMPURITY STANDARD NO.1 SUPPLIER & MANUFACTURER
Run for science and technology, promote human health
Location: Home > NEWS & INSIGHTS

2024V25 | Stability Study of Specific Impurities in Dapoxetine for the Treatment of Premature Ejaculation

Time:2024-10-09


Introduction

 

Today, we present a study on the stability of specific impurities in Dapoxetine, a pharmacological treatment for premature ejaculation (PE) in men aged 18 to 64 years who experience significant personal distress, interpersonal challenges, and inadequate ejaculatory control due to PE.

 

 

 

Experimental Scheme


In this study, our center conducted an investigation into the solution stability of three specific impurities in Dapoxetine hydrochloride, referencing the chromatographic conditions outlined under the Related Substances check item in the import registration standard for Dapoxetine Hydrochloride Tablets (Standard Number: JX20150184). The sample numbers and structural formulas utilized are presented in FIG. 1 and FIG. 2.

 

图1.png 

Figure 1: The number and structure of impurity items utilized in this study


图2.png 

Figure 2: The correlation between the impurity codes specified in the standard and the impurity item numbers employed in this research

 

In this study, the research and development personnel took appropriate amounts of RM-D162401 (R320404; Dapoxetine Impurity A; CAS NO: 1346603-24-4), RM-D162405 (R319140; Dapoxetine Impurity E), and RM-D162406 (R316940; Dapoxetine Impurity F; CAS NO: 119357-18-5) and placed them in acidic, neutral, and alkaline solutions at room temperature and atmospheric pressure for durations of 0, 3, 6, 12, and 24 hours. This procedure followed the chromatographic conditions outlined under the check item "Related substances" in the import registration standard for Dapoxetine Hydrochloride Tablets (Standard No. JX20150184). The stability of the sample solution will be assessed by monitoring changes in the main peak area on the chromatogram as a function of storage time.

 

 

 

 

Experimental Results

Upon testing, we observed that the peak-to-peak area of samples RM-D162401 (R320404), RM-D162405 (R319140), and RM-D162406 (R316940) exhibited minimal variation over a 24-hour period in acidic, neutral, and alkaline solutions, with a relative standard deviation of less than 2.0%. Consequently, these three samples can be regarded as relatively stable when subjected to acidic, neutral, and alkaline environments for 24 hours. The main peak area data for each detection point of the aforementioned samples across different pH values is presented below:


图3.png 

Figure 3: Schematic representation of the stability data summary for sample RM-D162401


图4.png 

Figure 4: Schematic representation of the summary data on solution stability for sample RM-D162405


图5.png 

Figure 5: Schematic representation of the stability data summary for sample RM-D162406

 

 

 

Experimental conclusion


In conclusion, our experiment demonstrated that the three specific impurity samples of Dapoxetine—RM-D162401 (R320404), RM-D162405 (R319140), and RM-D162406 (R316940)—exhibited commendable stability across acidic, alkaline, and neutral solutions.  For inquiries concerning the stability characteristics of these three samples, please do not hesitate to contact our company.


屏幕截图 2024-04-15 092448.jpg


Back

CONTACT US

Service hotline: +86 0755-66853366
Marketing Department: +86 136 7004 6396 (WeChat)
Email: sales@chem-strong.com
Office address: Room 1201, Jiaye Plaza, No. 2055, Bixin Road, Longgang District, Shenzhen

*All of our products are for R&D use only, and cannot be used in human or animal clinical use

FOLLOW US

ChemStrong

QCS R&D Center

Copyright 2006-2024 © ShenZhen ChemStrong Scientific Co., Ltd. 备案号:粤ICP备19155981号 Shenzhen Municipal Administration for Market Regulation Enterprise Identity Disclosure

CONTACT US

Service hotline: +86 0755-66853366
Marketing Department: +86 136 7004 6396 (WeChat)
Email: sales@chem-strong.com
Office address: Room 1201, Jiaye Plaza, No. 2055, Bixin Road, Longgang District, Shenzhen
*All of our products are for R&D use only, and cannot be used in human or animal clinical use

FOLLOW US

ChemStrong

QCS R&D Center

Copyright 2006-2024 © ShenZhen ChemStrong Scientific Co., Ltd. 备案号:粤ICP备19155981号 Shenzhen Municipal Administration for Market Regulation Enterprise Identity Disclosure